Helium Research Center internal report
By J.E. Miller
Subjects: Viscosimeter|Data processing, Atmospheric temperature, Helium, Mathematical models, Viscosimeter
Description: Analytic solutions for correction of non-uniformity in viscosimeter capillary bores are presented for the following cases: ellipse, cone, sine wave, sawtooth wave, square wave, and the general case.